Skip to content
Snippets Groups Projects

Resolve "Modifier l'avertissement de limite d'ennoiement de Villemonte"

3 files
+ 3
3
Compare changes
  • Side-by-side
  • Inline
Files
3
@@ -4,7 +4,7 @@
"WARNING_DEVER_ZR_SUP_Z1": "Elevation of the river bed can't be higher than water elevation: Impossible to calculate the kinetic energy",
"WARNING_DOWNSTREAM_ELEVATION_POSSIBLE_SUBMERSION": "Downstream elevation is higher than weir elevation (%submergencePerc%% submergence)",
"WARNING_ORIFICE_FREE_DOWNSTREAM_ELEVATION_POSSIBLE_SUBMERSION": "Downstream elevation is higher than orifice center elevation (%submergencePerc%% submergence)",
"WARNING_NOTCH_SUBMERGENCE_GREATER_THAN_07": "Notch submergence (%submergencePerc%%) is higher than recommended boundary (70%)",
"WARNING_NOTCH_SUBMERGENCE_GREATER_THAN_09": "Notch submergence (%submergencePerc%%) is higher than recommended boundary (90%)",
"WARNING_SLOT_SUBMERGENCE_NOT_BETWEEN_07_AND_09": "Slot submergence (%submergencePerc%%) is not in the recommended boundaries (70 to 90%)",
"ERROR_STRUCTURE_SUBMERGENCE_LOWER_THAN": "Slot submergence (%submergencePerc%%) is lower than %min%%",
"WARNING_WEIR_SUBMERGENCE_LOWER_THAN_08": "Weir submergence factor (%submergencePerc%%) is lower than the recommended boundary (80%)",
Loading